Flat 3 Cremer Street Home User Guide

Jumper Settings For Zone 1 to operate as a master zone the following steps must be adhered to: 5 Zone Panel Step 1 The following jumpers should be enabled for zone 1 to act as a master: J16, J18, J19 Jumpers J20 – J24 configure zones 1-5 respectively to operate alongside zone one. E.g Jumper J23 will enable zones 2-4 to act in tandem with the master zone. Therefore zone 5 will remain operating independently. Step 2 Remove Jumper J29 – Note there must be no trigger input at terminal J33 (Link1). 10 Zone Panel Step 1 The following jumpers should be enabled for zone 1 to act as a master: Upper circuit board: J16, J18, J15 Jumpers J20 – J24 configure zones 1-5 respectively to operate alongside zone one. If using more than 5 zones with the master insert a jumper on to J24 to continue the master on to the lower circuit board. Lower circuit board: J17 Jumpers J20 – J24 configure zones 6-10 respectively to operate alongside zone one. E.g Jumper J23 will enable zones 2-9 to act in tandem with the master zone. Therefore zone 10 will remain operating independently. Step 2 Remove Jumper J29 on upper circuit board (zone 1) – Note there must be no trigger input at terminal J33 (Link1). Step 3 Connect two cables between circuit board 1 and circuit board 2: Cable 1: Board 1 Master Connection OUT  Master Connection IN Board 2 Cable 2: Board 2 Master Connection OUT  Master Connection IN Board 1 Example for AOV20-10 with zone one as a master. Once step 3 is completed: Upper board: J15, J16, J19, J24 Lower Board: J17, J24.