Technical data - SX 7. TECHNICAL AND PERFORMANCE SPECIFICATIONS
SX 120 SX 150 SX 180 SX 210 SX 250 SX 300 - 10802661 10802662 10802663 10802664 10802665 10802666 - 7070644007171 7070644007188 7070644007195 7070644007201 7070644007218 7070644007225
Description Part number GTIN number
Unit
242 580 1550 59 301 35 21 62 1.488 37.2 4507
L.
111
143 580
164 580 1160
193 580
281 580
Actual capacity of the water tank at 20°C
mm 580 mm 870
Outer diameter of the tank Height of the appliance Gross weight of the appliance
1050
1300
1750
kg kg
37
42
47
52
65
148
185
211
245
346
Net weight of appliance once filled with sanitary water
- incoloy 825 incoloy 825 incoloy 825 incoloy 825 incoloy 825 incoloy 825 - PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP*
Material of element
Thermal insulation material
mm 35
35 21
35 21
35 21
35 21
Thermal insulation of the tank, average thickness
-
21
IP classification
0.96
1.128
1.224 1.344
1.632
Standby heat loss / 24 hour
kWh/24h
Watts
40
47
51
56
68
Standby heat loss
% 37.2 kWh 2752
37.6 4453
37.2 4499
37.8 4434
37.3 4490
Thermal energy efficiency
Annual Electrical Consumption (AEC)
XL 386 900 297 208 132 92
ErP
L
XL
XL
XL
XL
Load profile
L.
162 900 130
254 900 174
304 900 201
323 900 235 165 135
463 900 347 243 132
Hot water capacity(1) >40°C
l/h
Primary flowrate for Reheat time & Primary heating power
min min min min
Heat up (bottom element) 10°C - max Recovery (bottom element) after 70% Heat up (top element) 10°C - max Recovery (top element) after 70%
91
121 74 52
141 101
N/A N/A
71
95
92
C
Rating C
C
C
C
C
ErP class
Pressure information Maximum design pressure of cylinder (rated pressure)
MPa/Bar 1 / 10 1 / 10 1 / 10 1 / 10 1 / 10 1 / 10
3
MPa/Bar
3
3
3
3
3
Operating pressure of cylinder
70
°C
70
70
70
70
70
Max. operating temperature of cylinder
Aquasys tem 3 bar
- GWS 3.5bar GWS 3.5bar GWS 3.5bar GWS 3.5bar GWS 3.5bar
Expansion solution
L.
6
2 x 6
2 x 6
2 x 6
2 x 6
24
Expansion vessel capacity Hydraulic connections Secondary return
15
mm 15 Inch 3/4” Inch 3/4” Inch 5/4” Inch 1/2” Inch 1/2” Inch 3/4”
15
15
15
15
3/4” 3/4” 5/4” 1/2” 1/2” 3/4”
3/4” 3/4” 5/4” 1/2” 1/2” 3/4”
3/4” 3/4” 5/4” 1/2” 1/2” 3/4”
3/4” 3/4” 5/4” 1/2” 1/2” 3/4”
3/4” 3/4” 5/4” 1/2” 1/2” 3/4”
Cold water Hot water
Immersion heater
Safety valve (factory fitted) T&P valve (factory fitted) Pressure reducing valve Electrical characteristics Supply voltage and frequency
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V
VAC/Hz
kW
Power of the electrical resistance
- -
IET regs IET regs IET regs IET regs IET regs IET regs
Electrical installation
Thermostat type - junction box Immersian Heater - Phase Immersion thermostat - temp range Immersion thermostat - set temp Safety Safety valve opening pressure +/- 5% T&P valve opening pressure/Temp. Safety thermostat cutout - Top Safety thermostat cutout - Bottom
Surface
Surface
Surface
Surface
Surface
Surface
Phase single single single single single single °C 40-70 40-70 40-70 40-70 40-70 40-70
70
°C
65
70
70
70
70
8
Bar
8
8
8
8
8
Bar/°C 10/90 10/90 10/90 10/90 10/90 10/90
85 85
°C °C
N/A
85 85
85 85
85 85
85 85
85
*Vacuum Insulation Panels
15