17-48 Melfield Gardens

Technical data - SX 7. TECHNICAL AND PERFORMANCE SPECIFICATIONS

SX 120 SX 150 SX 180 SX 210 SX 250 SX 300 - 10802661 10802662 10802663 10802664 10802665 10802666 - 7070644007171 7070644007188 7070644007195 7070644007201 7070644007218 7070644007225

Description Part number GTIN number

Unit

242 580 1550 59 301 35 21 62 1.488 37.2 4507

L.

111

143 580

164 580 1160

193 580

281 580

Actual capacity of the water tank at 20°C

mm 580 mm 870

Outer diameter of the tank Height of the appliance Gross weight of the appliance

1050

1300

1750

kg kg

37

42

47

52

65

148

185

211

245

346

Net weight of appliance once filled with sanitary water

- incoloy 825 incoloy 825 incoloy 825 incoloy 825 incoloy 825 incoloy 825 - PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP* PUR+VIP*

Material of element

Thermal insulation material

mm 35

35 21

35 21

35 21

35 21

Thermal insulation of the tank, average thickness

-

21

IP classification

0.96

1.128

1.224 1.344

1.632

Standby heat loss / 24 hour

kWh/24h

Watts

40

47

51

56

68

Standby heat loss

% 37.2 kWh 2752

37.6 4453

37.2 4499

37.8 4434

37.3 4490

Thermal energy efficiency

Annual Electrical Consumption (AEC)

XL 386 900 297 208 132 92

ErP

L

XL

XL

XL

XL

Load profile

L.

162 900 130

254 900 174

304 900 201

323 900 235 165 135

463 900 347 243 132

Hot water capacity(1) >40°C

l/h

Primary flowrate for Reheat time & Primary heating power

min min min min

Heat up (bottom element) 10°C - max Recovery (bottom element) after 70% Heat up (top element) 10°C - max Recovery (top element) after 70%

91

121 74 52

141 101

N/A N/A

71

95

92

C

Rating C

C

C

C

C

ErP class

Pressure information Maximum design pressure of cylinder (rated pressure)

MPa/Bar 1 / 10 1 / 10 1 / 10 1 / 10 1 / 10 1 / 10

3

MPa/Bar

3

3

3

3

3

Operating pressure of cylinder

70

°C

70

70

70

70

70

Max. operating temperature of cylinder

Aquasys tem 3 bar

- GWS 3.5bar GWS 3.5bar GWS 3.5bar GWS 3.5bar GWS 3.5bar

Expansion solution

L.

6

2 x 6

2 x 6

2 x 6

2 x 6

24

Expansion vessel capacity Hydraulic connections Secondary return

15

mm 15 Inch 3/4” Inch 3/4” Inch 5/4” Inch 1/2” Inch 1/2” Inch 3/4”

15

15

15

15

3/4” 3/4” 5/4” 1/2” 1/2” 3/4”

3/4” 3/4” 5/4” 1/2” 1/2” 3/4”

3/4” 3/4” 5/4” 1/2” 1/2” 3/4”

3/4” 3/4” 5/4” 1/2” 1/2” 3/4”

3/4” 3/4” 5/4” 1/2” 1/2” 3/4”

Cold water Hot water

Immersion heater

Safety valve (factory fitted) T&P valve (factory fitted) Pressure reducing valve Electrical characteristics Supply voltage and frequency

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

220-240 VAC 50 Hz 3.0kW@240V 2.8kW@230V

VAC/Hz

kW

Power of the electrical resistance

- -

IET regs IET regs IET regs IET regs IET regs IET regs

Electrical installation

Thermostat type - junction box Immersian Heater - Phase Immersion thermostat - temp range Immersion thermostat - set temp Safety Safety valve opening pressure +/- 5% T&P valve opening pressure/Temp. Safety thermostat cutout - Top Safety thermostat cutout - Bottom

Surface

Surface

Surface

Surface

Surface

Surface

Phase single single single single single single °C 40-70 40-70 40-70 40-70 40-70 40-70

70

°C

65

70

70

70

70

8

Bar

8

8

8

8

8

Bar/°C 10/90 10/90 10/90 10/90 10/90 10/90

85 85

°C °C

N/A

85 85

85 85

85 85

85 85

85

*Vacuum Insulation Panels

15