section). Connect the wires to the terminal block. With recessed wiring, ensure the rear gasket seals around the edge of the hole in the ceiling or wall. This is to prevent air draughts affecting the smoke/heat entering the Alarm. If the hole is too large or the Alarm does not seal it, it should be sealed with silicone rubber or equivalent. 6. Replace the wiring cover and carefully line up the Alarm on the mounting plate and slide on (see Figure 7). 7. Connect the mains power to the Alarm circuit. Check the green light on the front of the Alarm is on. 8. Press and hold the test/hush button for 10 seconds (see Figure 8). The alarm will sound. Check that any interconnected Alarms also sound within this period. The test/hush button sounds the local alarm and on release this alarm stops immediately, and all the interconnected Alarms can then be heard in the distance as they will continue to sound for a further 3 seconds. 9. Attach the ’fuse board label’ provided on or near the distribution board and write in date installed and the number of Alarms on the circuit. 10. Ensure the Alarm operates correctly - see TESTING and MAINTAINING YOUR ALARM section. Slide on the Alarm Test Alarms Fig.7 Fig.8