2.4 Where in the room? The locations must comply with applicable building regulations

Ceiling Mounting Hot smoke rises and spreads out, so a central ceiling position is the preferred location. The air is “dead” and does not move in corners, therefore Alarms must be mounted away from corners. Fit the Alarm: - At least 300mm away from walls (see Figure 1). - At least 300mm from any light fitting or decorative object which might obstruct smoke / heat entering the Alarm. Wall Mounting (Ei3016 only) If ceiling mounting is impractical, only the Ei3016 Optical Smoke Alarm may be mounted on a wall, provided that: a) the top of the detection element is between 150mm and 300mm below the ceiling (see Figure 2); b) the bottom of the detection element is above the level of any door openings;

300mm (min)

300mm

Fig.1

150mm to 300mm

APEX

<600mm HEAT ALARMS <150mm SMOKE / MULTI-SENSOR ALARMS